JAAHA Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Oakley, R.
Right arrow Articles by Hauptman, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Oakley, R.
Right arrow Articles by Hauptman, J.
Journal of the American Animal Hospital Association, Vol 33, Issue 1, 77-82
Copyright © 1997 by American Animal Hospital Association


Articles

Experimental evaluation of central venous pressure monitoring in the dog

RE Oakley, B Olivier, GE Eyster, and JG Hauptman

The measurement of central venous pressure (CVP) will provide objective information about intravascular blood volume. Limitations exist with direct and indirect methods of measuring CVP; however, the purpose of this study was to determine if such factors as catheter size, patient position, or measurements taken with either a water manometer or a strain-gauge transducer would affect the accuracy of CVP measurements. The study population consisted of six adult, mixed-breed dogs. Catheter sizes evaluated were 16- and 19-gauge. Patient positions evaluated were right and left lateral recumbencies. Right atrial pressures (RAPs) were used as the reference standards for CVP measurements. Measurements of RAP and CVP were obtained with a water manometer and a strain-gauge transducer. No significant differences were observed in measured CVPs for the effects of catheter size and right versus left lateral recumbency. A 2.7-mmHg difference in water manometry was demonstrated when compared to strain-gauge transducer measurements. Also, strain-gauge transducer measurements had less precision compared to water manometer measurements.


This article has been cited by other articles:


Home page
Vet Rec.Home page
C. Lainesse, S. R. Boysen, and M. Y. Doucet
One-step method for catheterising the jugular vein of cats to enable repeated blood sampling
Vet Rec., August 18, 2007; 161(7): 221 - 225.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Animal Hospital Association.